Code: CSP03000020607TMM000
Short Description: Split PLC-WC-SM-1×08-TMM
Max. Dimensions of Telmex MSC fiber optic splitter: 40 x 4 x 4 mm
Input Fiber: 1.25 meter 250um (without connector)
Output Fiber:
- Total length: 1150mm.
- 830mm 8-channel ribbon + 15mm transition + 305mm
- 900um single loose tube. Without connector
- Fiber type 250 9m SM G.657.A2 (Compliant with G652D)
- Transition without Plastic Fan-Out piece. (see Appendix D)
Wavelength range: 1260-1650 nm
Optical features (without connectors): |
IL≤10.5 dB | IEC 61300-3-4 |
Uniformity: < 1 dB | IEC 61300-3-4 | |
RL > 55 dB | IEC 181 000 4.5.6 | |
PDL≤0.25 dB | IEC 61300-3-2 Method A | |
Directivity > 55 dB | EN 181 000 4.5.5 |
Connector Endface Inspection: Useless
Fiber colour: | Bellcore code: 1 groups of 8 fibers 1st group (1,2,3,4,5,6,7,8) |
Blue |
Orange | ||
Green | ||
Brown | ||
Slate | ||
White | ||
Red | ||
Black |
Test Reports Cons: All optical features above for 1260-1360nm and 1450-1650 nm, Mandatory: IL & RL results for 1310 – 1490 – 1550 nm for each output fiber
Packaging considerations: See Appendix A
Accessories: Fiber output tag/flag identifiers from 1 to 8
Generic Requirements:
- “Generic Requirements for Passive Optical Components” according to Telcordia GR-1209-CORE
- “Generic Reliability Assurance Requirements for Passive Optical Components” according to Telcordia GR-1221-CORE
- Except for those stated above and below this paragraph
Mechanical requirements:
Parameter | Test Method | Conditions | Requirements |
VIBRATION (sinusoidal) |
IEC 61300-2-1 | frequency: 10-55 Hz amplitude: 0.75 mm cycles: 15 time: 30min each perpendicular axis scanning time: 2 seconds (att. Measured at one splitter’s output) |
During and after the test – No change in splitter transmission parameters – IL: D ai≤0.5dB |
CORD TRACTION | IEC 61300-2-4 | magnitude of the force: with bare fiber: 5 N speed: 0.5 N/s point of appliance: 0.2 m from the end of connector time: 60 s |
During and after the test – No change in splitter transmission parameters – IL: D ai≤0.5dB |
CORD TORSION | IEC 61300-2-5 | magnitude of the force: 2 N max torsion angle: +180º, -180º cycles: 25 point of appliance: 0.2 m from the end of connector measure window: 1480-1580nm |
During the test – IL: D ai £ 0.5dB After the test – IL: D ai £ 0.3dB – RL ³ 55dB |
Environmental Requirements:
Parameter | Test Method | Conditions | Requirements |
COLD | IEC 61300-2-17 | temperature = -25ºC time: 96 h conditioning and recovery method: – 2h, 25ºC, 60%Hr – Max measure interval = 1h |
During the test – IL: D ai £ 0.5dB After the test – IL: D ai £ 0.10dB |
DRY HEAT | IEC 61300-2-18 | temperature = +75ºC time: 96 h conditioning and recovery method: – 2h, 25ºC, 60%Hr – Max measure interval = 1h |
|
TEMPERATURE CHANGE |
IEC 61300-2-22 | high temperature = +70ºC low temperature = -25ºC temperature change speed = 1ºC/min cycles = 12 time exposed to extreme temperatures: 1 h conditioning and recovery method: – 2h, 25ºC, 60%Hr – Max measure interval = 1h |
|
HUMIDITY | IEC 61300-2-19 | temperature = +40ºC Hr = 93%±2% time: 96 h conditioning and recovery method: – 2h, 25ºC, 60%Hr – Max measure interval = 1h |
|
WATER IMMERSION | IEC 61300-2-45 | Water column = 150mm Temperature = 43ºC Time = 168h |
|
SALT SPRAY | IEC 61300-2-26 | Saline solution: 5% pH = 6.5-7.2 temperature = +35ºC Hr = 60% time: 96 h |
After the test – IL: D ai £ 0.5dB – RL ³ 55dB |
DUST | IEC 61300-2-27 | Particle size: d<150um Dust type: talcum powder temperature = +35ºC Hr = 60% time: 10 min |
After the test – IL: D ai £ 0.5dB – RL ³ 55dB |
APPENDIX A: LABELS & PACKAGING FOR TELMEX MXC FIBER OPTIC SPLITTERS

Individual pack (plastic)



Small Box Package


Big Carton Box (for “x” units Small box)


APPENDIX B . Splitter Configuration Sample for 1×8 Alternative -1-

APPENDIX D. Splitter Configuration Example