TELMEX MXC FIBER OPTIC SPLITTER SPECIFICATION

Code: CSP03000020607TMM000

Short Description: Split PLC-WC-SM-1×08-TMM

Max. Dimensions of Telmex MSC fiber optic splitter: 40 x 4 x 4 mm

Input Fiber: 1.25 meter 250um (without connector)

Output Fiber:

  • Total length: 1150mm.
  • 830mm 8-channel ribbon + 15mm transition + 305mm
  • 900um single loose tube. Without connector
  • Fiber type 250 9m SM G.657.A2 (Compliant with G652D)
  • Transition without Plastic Fan-Out piece. (see Appendix D)

Wavelength range: 1260-1650 nm

Optical features
(without connectors):
IL≤10.5 dBIEC 61300-3-4
Uniformity: < 1 dBIEC 61300-3-4
RL > 55 dBIEC 181 000 4.5.6
PDL≤0.25 dBIEC 61300-3-2 Method A
Directivity > 55 dBEN 181 000 4.5.5

Connector Endface Inspection: Useless

Fiber colour:Bellcore code:
1 groups of 8 fibers
1st group (1,2,3,4,5,6,7,8)
Blue
Orange
Green
Brown
Slate
White
Red
Black

Test Reports Cons: All optical features above for 1260-1360nm and 1450-1650 nm, Mandatory: IL & RL results for 1310 – 1490 – 1550 nm for each output fiber

Packaging considerations: See Appendix A

Accessories: Fiber output tag/flag identifiers from 1 to 8

Generic Requirements:

  • “Generic Requirements for Passive Optical Components” according to Telcordia GR-1209-CORE
  • “Generic Reliability Assurance Requirements for Passive Optical Components” according to Telcordia GR-1221-CORE
  • Except for those stated above and below this paragraph

Mechanical requirements:

ParameterTest MethodConditionsRequirements
VIBRATION
(sinusoidal)
IEC 61300-2-1frequency: 10-55 Hz
amplitude: 0.75 mm
cycles: 15
time: 30min each perpendicular axis
scanning time: 2 seconds (att. Measured at one splitter’s
output)
During and after the test
– No change in splitter
transmission parameters
– IL: D ai≤0.5dB
CORD TRACTIONIEC 61300-2-4magnitude of the force:
with bare fiber: 5 N
speed: 0.5 N/s
point of appliance: 0.2 m from the end of connector
time: 60 s
During and after the test
– No change in splitter
transmission parameters
– IL: D ai≤0.5dB
CORD TORSIONIEC 61300-2-5magnitude of the force: 2 N
max torsion angle: +180º, -180º
cycles: 25
point of appliance: 0.2 m from the end of connector
measure window: 1480-1580nm
During the test
– IL: D ai
£
0.5dB
After the test
– IL: D ai
£
0.3dB
– RL ³ 55dB

Environmental Requirements:

ParameterTest MethodConditionsRequirements
COLDIEC 61300-2-17temperature = -25ºC
time: 96 h
conditioning and recovery method:
– 2h, 25ºC, 60%Hr
– Max measure interval = 1h
During the test
– IL: D ai
£
0.5dB
After the test
– IL: D ai £ 0.10dB

DRY HEATIEC 61300-2-18temperature = +75ºC
time: 96 h
conditioning and recovery method:
– 2h, 25ºC, 60%Hr
– Max measure interval = 1h
TEMPERATURE
CHANGE
IEC 61300-2-22high temperature = +70ºC
low temperature = -25ºC
temperature change speed = 1ºC/min
cycles = 12
time exposed to extreme temperatures: 1 h
conditioning and recovery method:
– 2h, 25ºC, 60%Hr
– Max measure interval = 1h
HUMIDITYIEC 61300-2-19temperature = +40ºC
Hr = 93%±2%
time: 96 h
conditioning and recovery method:
– 2h, 25ºC, 60%Hr
– Max measure interval = 1h
WATER IMMERSIONIEC 61300-2-45Water column = 150mm
Temperature = 43ºC
Time = 168h
SALT SPRAYIEC 61300-2-26Saline solution: 5%
pH = 6.5-7.2
temperature = +35ºC
Hr = 60%
time: 96 h
After the test
– IL: D ai
£
0.5dB
– RL ³ 55dB
DUSTIEC 61300-2-27Particle size: d<150um
Dust type: talcum powder
temperature = +35ºC
Hr = 60%
time: 10 min
After the test
– IL: D ai
£
0.5dB
– RL ³ 55dB

APPENDIX A: LABELS & PACKAGING FOR TELMEX MXC FIBER OPTIC SPLITTERS

Label: Logo + Product + Serial Nº.

Individual pack (plastic)

1×8: CSP03000020607TMM000
TELMEX MXC FIBER OPTIC SPLITTER
TELMEX MXC FIBER OPTIC SPLITTER
TELMEX MXC FIBER OPTIC SPLITTER
TELMEX MXC FIBER OPTIC SPLITTER

Small Box Package

always this label outside the box

Big Carton Box (for “x” units Small box)

always this label outside the box

APPENDIX B . Splitter Configuration Sample for 1×8 Alternative -1-

APPENDIX D. Splitter Configuration Example

Sample of 1×8. No FAN-OUT piece between ribbon and 900um fiber. Example: