Multi Operator Box Design Standard

  1.  Objectives 

This paper attempts to describe the needs Bouygues Telecom for the manufacture of boxes optical alternative suppliers to suppliers in place on the FTTH network Bouygues Telecom to obtain from these suppliers, substitution boxes (called ” alternative boxes “in the remainder of the document), compatible and interchangeable, in the case of maintenance in particular. 

This document also specifies the main characteristics of the multi operator boxes.

  1.  Document Reference 
Reference Date Title 
GR-1209-CORE 03/03/2001 Generic Requirements for Passive Optical Components 

  1. Terminology and acronym 
Title Definition 
PMI or BPI Pooling Point of Building – Case foot of the building or Case feet of property 
PRI Connection point of a building (or PMI) 
PDL Polarization-Dependent Loss – Losses by polarization (dB) 
Return loss Return Loss.  A contribution from the transmitted power and received power back to the input of the coupler 
Directivity Loss of power transmitted to an output port of the coupler to a different output port (dB) 
MEC96/128 Splicing module and coupling positions 96/128 
MBDT Modular Basement Distribution Terminal 

  1.  Contents of Delivery 

 The required service includes: 

  •  The evaluation grid completed (see § 9) 
  •  The manufacture of prototype housings conform to these specifications 
  •  The provision of associated documentation giving the technical specifications (mechanical and optical) prototypes 
  •  The test reports of cameras and couplers. 

  1.  Certifications and Standards 

 The boxes will comply with the essential health and safety as defined by EU directives, and standards. 

 The alternatives boxes must have the logo of  “laser radiation” code W010. 

 Pictogram: Rayonnement laser PIC 309

  1.  Requirements 
    1.  Compatibility with the boxes in place 

 Alternative Boxes must be fully compatible and interchangeable with the boxes from other vendors already on the FTTH network for Bouygues Telecom. 

  1.  Dimensions 

 The dimensions of the alternative boxes: Width (W) x height (H) x Depth (D) must be identical to the boxes in place:

    1.  Interfaces 

 Openings for cable entries or passages fiber boxes and garters of

alternative must be identical to those of the boxes in place (less important to the racks).

    1.  Anchoring Systems 

 Points or anchoring systems between boxes (pins, clips …) and the holes for wall mounting enclosures of alternatives must be identical to the boxes in place:

  1.  Esthetic 

 The alternative boxes should have a color identical to the boxes in place to ensure consistency of the overall aesthetics of the installation (less important to the racks).

  1.  Optical performance 
    1.  Performance of the couplers (not prohibitive) 

 The table below shows the expected performance of couplers and connectorized installed in enclosures (pigtails and body bushings included).

Characteristic 1×2 1×4 1×8 1×16 1×32 1×64 
Wavelength 1260 nm to 1650 nm 
Insertion Loss (dB) Min ≥ 2.4 ≥ 5.4 ≥ 8.1 ≥ 10.8 ≥ 13.1 ≤ 20 
Max ≤ 3.7 ≤ 7 ≤ 4.10 ≤ 5.13 ≤ 17 
Uniform output (dB) ≤ 0.6 ≤ 0.6 ≤ 1.0 ≤ 1.0 ≤ 1.3 ≤ 2.0 
PDL (dB) ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 
Return loss (dB) ≥ 55 dB 
Directivity (dB) ≥ 55 dB 
Fiber type Standard: G657A (15 mm radius) 
Output Type Standard: 250 microns fiber unit 
Temperature Operating and storage: -40 / +85 ° C 
Humidity Operating and storage: 93% humidity 
Standard Telcordia 1209 / 1221 

  1. Labeling / marking fiber output coupler 

 The fiber output splitter will be identified by means of rings numbered 1 to n.

 Examples: 

  •  Coupler 1×4 => 1, 2, 3, 4 
  •  1×16 coupler => 1, 2, …, 15, 16 

 In the case of a configuration with more couplers, color coupler ducts will be different for each module.

  1.  Description of Alternative 5 models of boxes 
    1.  Alternative Boxe A 

 These are alternative boxes to be installed on points of mutualisation of building FTTH in feet (PMI) which are already modules PRYSMIAN PRI 24. 

 These boxes must be able to alternate interface to the modules already deployed PRYSMIAN. 

  •  Coupling configuration to support:
    •  Case without coupling 
    •  1×8 
    •  1×8 + 1×8 
    •  1×16 
    •  1×32 

 Whatever the configuration above, the case will be equipped with the number of splice trays maximun allowing it to evolve into a complete filling.

  •  Interfaces between modules: 
    •  2 cable entries: one from above and from below on the left side of the module. 
    •  2 openings for the passage of fibers: one above and one below on the right side of the module. 
    •  Docking modules in pairs in the sense of height.  The module below clings to the one above by two anchor pins. 
  •  Dimension of module (mm): 
    •  445 (L) x 175 (H) x 102 (P) 
  •  Material: 
    •  Metal: Steel 
  •  Patch Panel: 
    •  Control up to 48 connectors 
    •  Locating connectors on the front of the patch panel 

  •  Connector type: SC / APC 
  •  Green adaptators : 
    •  Fixing by clips (option) 
    •  Closure by Valve 
  •  Finish: 
    •  Metal: Painting light gray (RAL 7035) 
  1.  Alternative B Boxe

 These are alternative boxes to be installed on points of mutualisation of building FTTH in feet (PMI), which are already present in the drawers MEC96 NEXANS. 

 These alternative boxes must be integrated into the bay NEXANS already deployed. 

  •  Coupling configuration to support: 
    •  Case without coupling 
    •  1×32 
    •  1×32 + 1×8 
    •  1×64 
    •  1×32 + 1×16 

 Whatever the configuration above, the case will be equipped to allow a move towards a complete filling. 

  •  Module Size (mm): 
  •  Material: 
    •  Metal: Steel 
  •  Patch Panel 
    •  Control up to 96 connectors 16 columns (labeled A to D) with six positions per column 
    •  Locating connectors on the front of the patch panel: 

  •  Connector type: SC / APC 
  •  Body crossings: 
    •  Fixing: clips 
    •  Closure by plugs (with valves optional) 
  •  Finish: 
    •  Metal: Painting light gray (RAL 9002 if possible) 
  1.  Alternative Boxe C 

 These are alternative boxes to be installed on points of mutualisation of building FTTH in feet (PMI), which are already present in the drawers MEC128 NEXANS. 

 These alternative boxes must be integrated into the bay NEXANS already deployed. 

  •  Coupling configuration to support: 
    •  Case without coupling 
    •  1×32 
    •  1×32 + 1×8 
    •  1×64 
    •  1v64 + 1V8 
    •  1×64 + 1×32 
    •  1×64 + 1×64 

 Whatever the configuration above, the case will be equipped to allow a move towards a complete filling. 

  •  Size: 
    •  Height (H): 3U 
    •  Width (W): 19 inches 
    •  Depth (D): 260 mm maximun 
  •  Material: 
    •  Metal: Steel 
  •  Patch Panel 
    •  Control up to 128 connectors: 16 columns (labeled A to D) with 8 positions per column 
    •  Locating connectors on the front of the patch panel: 

  •  Connector type: SC / APC 
  •  Green adaptators: 
    •  Fixing by clips : optional 
    • Closure  By plugs (with valves optional) 
  •  Finish: 
    •  Metal: Painting light gray (RAL 9002 if possible) 
  1.  Alternative D Cases 

 These are alternative boxes to be installed on points of mutualisation of building FTTH in feet (PMI), which are already present in modular housings MBDT Corning. 

 These boxes must be able to alternate interface to the modules already deployed MBDT Corning. 

  •  Coupling configuration to support: 
    •  Case without coupling 
    •  1V4 
    •  1V8 
    •  1V8 + 1V8 
    •  1v16 
    •  1v32 

 Whatever the configuration above, the case will be equipped with the number of splice trays to allow maximum movement towards a complete filling. 

  •  Size: 
    •  Height (H): 150 mm 
    •  Width (W): 454 mm 
    •  Depth (D): 155 mm 
  •  Material: 
    •  Metal: Steel 
  •  Patch Panel: 
    •  Control up to 48 connectors 
    •  Locating connectors on the front of the patch panel: 

  •  Connector type: SC / APC 
  •  Green adaptators: 
    •  Fixing  by clips 
    •  Closure cap (with valves optional) 
  1.  Alternative Boxe E

 These are alternative boxes to be installed on points of mutualisation of building FTTH in feet (PMI), which are already drawers HDC 3U Corning. 

 These alternative boxes must be integrated in the Bay Corning already deployed. 

  •  Coupling configuration to support: 
    •  Case without coupling 
    •  1×32 
    •  1×32 + 1×8 
    •  1×64 
    •  1v64 + 1V8 
    •  1×64 + 1×32 

 Whatever the configuration above, the case will be equipped to allow a move towards a complete filling. 

  •  Size: 
    •  Height (H): 3U 
    •  Width (W): 19 inches 
    •  Depth (D): 230 mm maximum 
  •  Material: 
    •  Metal: Steel 
  •  Patch Panel: 
    •  Control up to 128 connectors: 16 columns (labeled A to D) with 8 positions per column 
    •  The panel consists of four panels each comprising 32 modular connectors 
    •  Locating connectors on the front of the patch panel: 

  •  Connector type: SC / APC 
  •  Body crossings: 
    •  Fixing: clips 
    •  Closure by plugs  (with valves optional) 
  1.  Configurations of prototypes 

 By convention, each prototype will be named with a letter A, B, C, D and E respectively corresponding to the alternative case A, B, C, D and E. 

  1.  A prototype 
  •  Type of coupling: 1×32 
  •  Positions of pigtails on the patch panel: positions 1 to 32 
    1.  Prototype B 
  •  Type couplers: 1×32 + 1×16 
  •  Positions of pigtails on the patch panel: 
  •  positions A1 to F2 1×32 coupler 
  •  F3 H6 positions for 1×16 coupler 
  1.  Prototype C 
  •  Type couplers: 1×64 + 1×64 
  •  Positions of pigtails on the patch panel: 
  •  positions A1 to H8 for the first coupler 1×64 
  •  I1 to P8 positions for the second coupler 1×64 
  1.  Prototype D 
  •  Type of coupling: 1×32 
  •  Positions of pigtails on the patch panel: A1-A8-B8 + B1 + C1-C8 + D1-D8 
  1.  Prototype E 
  •  Type couplers: 1×64 + 1×32 
  •  Positions of pigtails on the patch panel: 
  •  Positions A1 to H8 for the coupler 1×64 
  •  I1 to positions L8 1×32 coupler for 

Prysmian Multi Dwelling Unit Wall Box (MDU) (WM008-06) is complied to this standard.