1. General requirements
Fiber optic duct closures must be suitable for installation in cable ducts in the Nokia network. The closures must be able to connect cables of loose tube construction with G652/G657 fibers while maintaining an appropriate bending radius.
2 Application table
The following table in Table 1.1 shows the minimum requirements for closure configurations in the different application variants.
Table 1.1 – Minimum requirements for the configuration of the 1FCP closure in different application variants.
Location | Splitter / Patching | 48F | 72F | 96F | 144F |
Mounting in Cable ducts | No Splitter | YES | YES | YES | YES |
Two Splitter(1:8 or 1:4) | YES | YES | |||
No patching field | YES | YES | YES | YES | |
Patching field | YES |
3. Total closure capaciy
The closure must be able to do so:
- making of 48/72/96/144 fiber optic splices,
- Installation up to 2 optical splitters (1:8 or 1:4) in a mini-metal-box enclosure,
- Mounting of at least 18 SC/APC adapters.
4. Construction
The closures should be of multiple access design. The design must be such that it is possible to integrate with the cable overlength frame. The closure must be equipped with a minimum:
- 2 round ports for cable entry with diameters from 8 mm to 15 mm, mechanically or thermally sealed,
- 1 oval (double) port for cable entry with diameters from 5 mm to 15 mm without cutting through cable tubes, mechanically or thermally sealed,
- 8 round ports from 5 mm to 8.2 mm mechanically sealed.
The closure must have a fixture for the cable strength element, which prevents the cable from being pulled out. The construction of the closure must allow it to be installed in a cable container with a room for closure with holders for a 275 mm diameter and 385 mm long.
5 Basic closure equipment
Each closure should be equipped with:
- splice trays for a minimum of 72 splices,
- space for a minimum of 2 splitters in a mini-metal-box enclosure (1:4, 1:8),
- cable port seals,
- Cable ties,
- bracket for fixing the cable strength element,
- the necessary screws and mounting tapes,
- closure mounting bracket for mounting the closure on the manhole wall.
6. Additional closure accessories
Each closure should be expandable with the following elements:
- additional splice trays enabling the expansion of the closures to 144 splices or a bracket for the assembly of at least 18 patching ports,
- splicing H/S protectors,
- Cable overlength frame with mounting bracket integrated in the closure, enabling installation in the manhole,
- SC/APC adapters.
7. Temperature range
- Installation: from -10OoC to +60oC
- Transport and storage: from -40oC to +70oC
- Operation: -30oC to +70oC
8. Functional requirements
The following table in Table 1.2 shows the functional requirements for the 1FCP fiber optic duct closure.
Application | Ducts (M/H, H/H) |
Underground/wall/pole installation(U/W/P) | U (underground) |
IP rating | IP67 or higher |
Maximum dimensions(LxWxH) [mm xmm xmm] | 450x300x200 |
Portection against UV(carbon black index %) | 2.5 ± 0.5 |
Minimum number of ports | 11 |
Input cable diameter(mm) | 5 to 15 |
Number of splices | 48/72/96/144 |
Bending radius (mm) | |
G652 | 30 |
G657 | 15 |
Splice tray capacity | 12 or 24 |
Minimum FO cable extra-length (in cm) in conversion to the fibre | 250 |
Mid-span splicing option (Y/N) | Y |
Splitter installation (minibox) 1×4, 1×8 (Y/N) | Y |
Sealing (Mechanical (M) / Heat Shrinkable (HS)) | M/HS |
Tray marking (Y/N) | Y |
1.9 Test
The manufacturer will provide Nokia with references to standards. The tests listed below are Nokia’s minimum requirements.
1.9.1 General test
No chemical reaction, even in the long term, between all components and the material used in the production of the closure: plastics, metal, covers, filling, glue, fiber optic cables FO, PEHD, etc. The material used must not pose a risk to health or safety. A safety certificate must be presented. The closure should be UV-resistant according to the defined black carbon index. The closure cover must be resistant to solvents.
1.9.1.1 Quality control – inspection and measurement
Measurements will be carried out using standard methods. The supplier will provide Nokia with references to standards. This section contains criteria for the visual and mechanical inspection of fiber optic fragments, connectors and passive components. The control method may be used at any stage of the qualification or quality assurance process, as a self-test, or as a test required by the corresponding specification. The closure must not bear any visual signs of damage. The marking shall be legible and in accordance with the relevant specification. Dimensions must be in accordance with the documentation.
1.9.1.2 Dimensions
Dimensions must comply with the specification.
1.9.1.3 Sealing
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.4 Repair
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.5 Environmental and transport conditions
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.6 Mechanics
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.7 Immersion in water and temperature fluctuations
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.8 Temperature changes
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.9 Vibration (sinusoidal)
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.10 Optical fibre/cable retention
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.11 Twisting the fiber optic cable
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.12 Flexibility before pulling out
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.13 Shock
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.14. Impact force
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.15 Climatic test specification
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.16 Acid environment
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.17 Alkaline environment
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.18. Environment of surfactants
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.19 Resistance to UV rays
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.
1.9.1.20 Resistance to salt spray
The audit will be carried out using standard methods. The manufacturer will provide Nokia with references to standards.